Connected
Proposal and test · Line B · Moulding

Hold pressure: 700 to 720 bar

Hold pressure 700 to 720 bar · optimiser opt 2.3.8 · raised 8 Oct 14:00
All proposals
Process agent·Line B·Press P3·Hold pressure 700 to 720 bar·14:00StayHolding

Raise hold pressure from 700 to 720 bar

Sink marks on rib side.

Expected result
MeasuredScrap rate3.4 %90% interval 3.1 to 3.8
Spec 0 to 4 % (dashed). Driven by Hold pressure.
Why this confidence
Method
Optimiser opt 2.3.8; band from the model of the machine; weakest input measured
Model fit
Accepted, four checks passed
Safety filter
Passed: Inside narrowed band
Evidence
EV-B-1902
Limits
Hold pressure700 barto 720 bar
600640 to 820 narrowed860
Signed by Plant head A. · 20 SeptStamped narrowingNowProposed
If stoppedStop keeps the value and writes nothing new.
DecidedOperator D. · 8 Oct 15:00
NoticedProposedWaitingstayMeasuringVerdictHolding

Test on the model of the machine

Predicted scrap rate
MeasuredScrap rate3.4 %90% interval 3.1 to 3.8
Spec 0 to 4 % (dashed). Driven by Hold pressure.
Why this confidence
Method
Model Line model B b-1.6; band is the model's 90% interval; no single score is documented for proposals
Model fit
Accepted, four checks passed
Safety filter
Passed: Inside narrowed band
Evidence
EV-B-1902
Scrap rate, last 12 shift runs40
CheckResultDetail
Safety filterPassedInside narrowed band
Model fitAcceptedLine model B b-1.6, coverage 91% on 214 held-out points
Weakest inputMeasuredA claim is as strong as its weakest load-bearing input
Inside the windowYesSigned 600 to 860 bar, narrowed 640 to 820

Model fit · Line B

Accepted
90% interval coverage on 214 held-out points91%
70%85 to 95% accepted100%
  • PassHeld-out error0.21 % scrap
  • Pass90% interval coverage91%
  • PassNo drift in residualsflat, 30 d
  • PassPhysical limits respectedall
Calibrated 12 Oct. Proposals on this line may carry a number. Model fit

Runs this rests on

Recent runs
RunHold pressureScrap rate
Shift run 6797203.76
Shift run 6787203.4
Shift run 6777203.57
Shift run 6767203.3
Shift run 6757203.71
Shift run 6747203.57

Came from Quality

Light parts on cavity 2Quality head A. · lot Lot 7711 · raise hold-pressureCorrections to process

History

  • 8 Oct 14:00Proposed by optimiser opt 2.3.8
  • 8 Oct 15:00Decided by Operator D.