Connected
Asset · Line A · Batch mixing

Jacket loop

2 tags · key reading Jacket inlet temperature

Jacket inlet temperature

Jacket flow

Parameters

Readings
TagValueQualityLabelRunAt
Jacket inlet temperature87.0 °CgoodMeasuredBatch 241920 Oct 09:40
Jacket inlet temperature86.6 °CgoodMeasuredBatch 241920 Oct 10:15
Jacket inlet temperature87.1 °CgoodMeasuredBatch 241920 Oct 10:50
Jacket inlet temperature87.0 °CgoodMeasuredBatch 241920 Oct 11:25
Jacket flow10.8 m³/hgoodMeasuredBatch 241920 Oct 09:40
Jacket flow10.6 m³/hgoodMeasuredBatch 241920 Oct 10:15
Jacket flow10.8 m³/hgoodMeasuredBatch 241920 Oct 10:50
Jacket flow10.8 m³/hgoodMeasuredBatch 241920 Oct 11:25

Events

  • 06:10Shift 1 started, handover read by Shift lead A.
  • 09:45Lab results late from the lab system; 4 lots unanchored
  • 11:00Batch 2417 written at 86 °C (trial arm B)
  • 12:30Lot 3307 flagged at risk on viscosity
  • 13:20Agitator speed proposal on Mixer M1

Reading quality

Quality
TagGoodUncertainBad
Jacket inlet temperature6660
Jacket flow7200

Setpoint writes

Writes
SettingToSourceAt
agitator150prior20 Oct 05:02
hold-time55prior20 Oct 05:01
hold-temp84prior20 Oct 05:00
agitator150prior19 Oct 20:02
hold-time55prior19 Oct 20:01
hold-temp86proposal19 Oct 20:00
agitator150prior19 Oct 11:02
hold-time55prior19 Oct 11:01

Facts

Line
Line A · Batch mixing
Mode
Trial
Tags
Jacket inlet temperature, Jacket flow
Section
3 by 1 on the line map
Data
Plant historian

Running settings

Hold temperature86 °C · band 80 to 90 · until 14:00Trial
Hold time55 min · band 40 to 70 · until 14:00Stay
Agitator speed150 rpm · band 130 to 170 · until 14:00Stay