Connected
Investigation · open

High viscosity on Grade A-12

Opened by Quality head A. · 2 lots · 2 runs
Evidence

Case file

  • 17 Oct 14:00evidence · Viscosity drifting up over 9 batches Measured
  • 18 Oct 14:00link · Lots 3307 and 3296 linked to batches 2416 and 2417 Estimated
  • 19 Oct 14:00note · End-of-hold torque high on both; charge mass in recipe Measured

Lots in this case

Lots
LotRiskPredictedSpecJoinLinks
3307At risk2540 to 2630 mPa·s2380 to 2600estimated0.93, 0.86
3296At risk2540 to 2630 mPa·s2600 to 2840estimated0.86, 0.93

Linked runs

Conclusion

Open. A conclusion is written once the evidence answers the question.

Quality head can send corrections

Proof record

No changeR2Unknown
Effect Viscosity vs predicted +12 mPa·s, interval -30 to 54 mPa·s.
Why this confidence
Method
Before and after on matched lots
Diagnostics
Unanchored until lab result
Open the four questions

Corrections from this case