InconclusiveR2Unknown
Withheld: needs 6 more batches. Effect Time to target viscosity -4.1 min, interval -8 to 0.4 min.
Why this confidence
- Method
- Measurement plan mp-1, locked before the trial
- Diagnostics
- Balance check passed; Carry-over check pending
- 1
Did the change happen as planned?
Yes, 9 of 10 switches written; 1 skipped and recorded
- 2
Did the outcome move?
Time to target fell 4.1 min on average
- 3
Could something else explain it?
Charge mass varied more on trial batches; not yet ruled out
- 4
Does it hold?
Too early: 10 of 16 batches
- Object
- trial trial-1
- Rung
- R2, not yet Verified (R3 or R4 needed)
- Measurement plan
- mp-1
- Method
- Switchback
Source rows
| Id | Tag | Value | Quality | Label |
|---|
| EV-A-1102 | Batch temperature 19 Oct 14:00 | 86.1 °C | Good | Measured |
| EV-A-1120 | Viscosity 19 Oct 14:00 | 2,471 mPa·s | Good | Estimated |
| EV-A-1131 | Charge mass 19 Oct 14:00 | 1,204 kg | Uncertain | Measured |