Connected
Activity

Audit log

Who approved, overrode, stopped and signed, with before and after. Read only; entries cannot be edited or removed.
Export audit extract

Events

Audit events
TimePersonActionObjectBefore → afterLineSource
20 Oct 07:46Plant head A.Plant headSigned trial orderHold temperature trial, Line ANo value changeLine Ain-app
19 Oct 19:18Process engineer A.Process engineerNarrowed limitHold temperature window, Line A78 to 92 °C80 to 90 °CLine Ain-app
18 Oct 18:22Plant head A.Plant headSigned trial orderHold temperature trial, Line ANo value changeLine Ain-app
18 Oct 05:54Process engineer A.Process engineerNarrowed limitHold temperature window, Line A78 to 92 °C80 to 90 °CLine Ain-app
17 Oct 04:58Plant head A.Plant headSigned trial orderHold temperature trial, Line ANo value changeLine Ain-app
16 Oct 16:30Process engineer A.Process engineerNarrowed limitHold temperature window, Line A78 to 92 °C80 to 90 °CLine Ain-app
15 Oct 15:34Plant head A.Plant headSigned trial orderHold temperature trial, Line ANo value changeLine Ain-app
15 Oct 03:06Process engineer A.Process engineerNarrowed limitHold temperature window, Line A78 to 92 °C80 to 90 °CLine Ain-app
14 Oct 02:10Plant head A.Plant headSigned trial orderHold temperature trial, Line ANo value changeLine Ain-app
13 Oct 13:42Process engineer A.Process engineerNarrowed limitHold temperature window, Line A78 to 92 °C80 to 90 °CLine Ain-app

Pressed Stop

Illustrative
When
20 Oct 04:39 IST · 9 h ago
Person
Operator C., Operator
Object
trial Hold temperature trial, Line A
Line
Line A · Batch mixing
Source
Decided in Stamped

Before and after

This event did not change a value. It records a decision about Hold temperature trial, Line A.

Evidence on the object

Trial
Hold temperature 84 to 86 °C on Grade A-12
Stop
Restored 84 °C for batch 2409; trial resumed next batch after review; restored

Other events on this object

By person

By person
PersonEventsLast
Plant head A.5Signed trial order6 h ago
Process engineer A.5Narrowed limit19 h ago